SC03 vehicle test Fahrtwind-Simulators VRSF/VAF

With LTG SC03-Fahrtwind-Simulators, a uniform air distribution over an air outlet area of 1.7 m² is achieved, as required by CFR § 1066 for SC03 tests up to 60 mph (96 km/h). Whether ambient temperatures down to -40 °C, a variable air outlet height or limited space availability in the test cell, with our stationary and mobile Fahrtwind-Simulators we offer complete system solutions for the implementation of SC03 vehicle tests for every requirement.

Optional an additional nozzle for reaching higher air outlet speeds can be installed, e.g. for WLTP tests up to
135 km/h.

Technical data

TypeAverage outlet velocity [mph]Outlet area Hx W [inch]Air outlet height above floor [inch]Air volume [cfm]Ambient temperature [°F]Requirements
VRSF 1120 E40306039.4 x 676 - 1896 00040 to +122SCO3, CFR
8531.5 x 39.48 - 2064 500-40 to +122CFR
9031.5 x 39.48 - 2068 300+14 to +122CFR
8423.6 x 39.48 - 2047 700-40 to +122WLTP
VRSF 1120 E396110039.4 x 31.5275 300+14 to +113RDE, WLTP
VAF 2x1120 E40046039.4 × 67696 000+50 to +104SC03, CFR
VAF 2500 E393411243.3 x 78.78 - 20235 400+32 to +104
VAF 2240 E3949/E390410039.4 x 78.78 - 20188 300+32 to +104
VAF 2240 E37949070.9 x 41.34159 000+50 to +104
VAF 2240 E38479039.4 x 78.7 360° rotatable-170 500+14 to +104
VAF 14006028 x 55 11559 000+50 to +104

Downloads

Short Information Fahrtwind-Simulators VQF Comfort Drive
PDF 557.52 kB
Short Information Maintenance & calibration measurement Fahrtwind-Simulators VQF/VAF
PDF 712.1 kB
Short Information Fahrtwind-Simulators SC03
PDF 627.14 kB
Technical brochure Fahrtwind-Simulators VRSF/VAF
PDF 4.28 MB

Impressions