The barely visible ceiling unit is particularly suitable for full height glazing without a raised floor. It is cooling only so needs to be combines with a baseboard or ceiling mounted heating solution.

All versions of the FVP family imitates human breathing thanks to the PulseVentilation design, allowing the space to breathe “naturally” through a single opening in the building skin. By alternating the airflow direction through the unit, highly efficient heat recovery is achieved all year round, unique for this type of solution, maximizing the customers energy savings. The combination of a transient airflow with mixed displacement discharge provides good thermal comfort even at very low outside air temperatures.

  • Decentralized heating, cooling, dehumidification and filtering with instationary ventilation through only a single opening in the building skin per unit
  • Unique economic efficiency through highly efficient heat recovery (heat recovery efficiency up to 90%) and demand-based control concepts
  • Draft-free and low-noise pulse flow up to 75 cfm (150 cfm in hybrid ventilation mode) with optimal ventilation effectiveness
  • Greater utilization of building footprint due to the major reduction of the space needed for the central plant, vertical chases and associated fire damper requirements and the duct distribution system and HVAC space requirements within the ceiling cavity
  • Lowest power consumption by minimised pressure loss (appx. 20 to 40 W per unit), corresponding to 10% of the SFP specification of the German Energy Conservation Ordinance (EnEV)
  • Year-round heat recovery reduces the investment costs for central boiler and chiller plant
  • Elimination in the potential for cross flow/cross contamination via a common duct distribution system, no remixing and redistribution via at a central plant, this is a 100% outside air system (DOAS) providing the occupant with fresh air all year round

An overview of all versions of the FVP family incl. technical data can be found in our brochure decentralized ventilation units.

LTG Connected Intelligence: Demand-based ventilation without the need for a central building management system with decentralized control intelligence. Efficient, scalable, bus-capable.

Coronavirus
We have compiled the most important facts and information on operation of air conditioning systems.

Ready for a breath of fresh air? Contact our comfort air experts now and breathe easy – literally!

Technical data

Technical Data for L_pa= 31 dB(A) NC = 26

Flow rate (entire circle) up to 75 cfm Flow rate (hybrid ventilation mode) up to 150 cfm Condensing operation Standard Max cooling output total 2935 Btu/h, room 2115 Btu/h 1) Heat recovery efficiency > 80 % 2) Electr. performance input 12 - 40 W Sound level (pA) 21 - 37 dB(A) 3)

Dimensions (Length x Width x Height in inch)

47.5 x 40 x 10.5